[Date Prev][Date Next][Thread Prev][Thread Next][Minivend by date
][Minivend by thread
]
Re: [mv] 2 machines
****** message to minivend-users from Mike Heins <mikeh@minivend.com> ******
Quoting Kġhegyi Tamás (tamas.kohegyi@lmf.ericsson.se):
> Well I new in INET mode could you explain the correct row (TcpHost) in the
> interchange.cfg?
>
> Anyway, I compiled the tlink.c again, then the problem was: - - - - -
> attempt to connect from unauthorized host 'UNRESOLVED_NAME/x.x.x.x' So I
> modified the Vend/Server.pm and I commented out the above check. (Is it a
> good solution???)
NO. Use the TcpHost directive in interchange.cfg.
>
> Then it was able to connect to the interchange server at the B, but now I got this error message:
>
> Undefined catalog: /vava/toll/ta
>
> The catalog name is 'ta'
> The '/Vava/Toll' is the place of the catalog html docs (not the cgi-bin).
> (like http://server/Vava/Toll/ta/index.html the start page /not an mv page/)
>
> So what did I wrong?
Your script name needs to match the Catalog line in interchange.cfg.
Good luck.
--
Akopia, Inc., 131 Willow Lane, Floor 2, Oxford, OH 45056
phone +1.513.523.7621 fax 7501 <heins@akopia.com>
Fast, reliable, cheap. Pick two and we'll talk. -- unknown
-
To unsubscribe from the list, DO NOT REPLY to this message. Instead, send
email with 'UNSUBSCRIBE minivend-users' in the body to Majordomo@minivend.com.
Archive of past messages: http://www.minivend.com/minivend/minivend-list